Evaluation of the use of saturated salt solutions for the museum relative humidity control

نوع المستند : مقالات بحثية

المستخلص

ABSTRACT
RH that is too high, too low or that fluctuates widely damages archaeological collections. Saturated salt solutions (Magnesium chloride, Sodium bromide, Potassium carbonate) have been used to obtain an equilibrium relationship of relative humidity and temperature. Over a temperature range 30˚C±2˚C.The experiments described in this research have the intention of creating known environmental conditions in containers where the linen textiles and metal samples are to be tested. The aim is to evaluate of saturated salt solutions to reach humidity to equilibrium state over a three-weeks and their effect on experimental samples. The scanning electron microscopy (SEM) and electron dispersive X-ray spectroscopy (EDX and EDS) analysis were used to detect the presence of salt ions deposition in samples. The mechanical characterize of textile samples were tested by tensile strength and elongation test

الكلمات الرئيسية

الموضوعات الرئيسية


1.      REFERENCES
1-Agrawal O. P., 1987. Conservation of Metals-Problems and Prospects. Proceedings of the Asian Regional Seminar. In: Conservation of Metals in Humid Climate. (eds): O. P. Agrawal, ICCROM, NRLC, (Rome), 1.
2-Ahmed H. E., 2013. Proteaes Enzyme Used For Artificial Ageing on Modern Cotton Fabric for Historic Textile Preservation and Restoration. International Journal of Conservation Science, 4, 2, ISSN: 2067-533X, 177-188.
3-Bacci M., Cucci C., Azelio Mencaglia A. A., Mignani A. G., 2005. Innovative Sensors for Environmental Monitoring in Museums", Sensors 8, 1984-2005.
4-Blaine R. , 2004. Humidity Fixed Points. TA Instruments, USA, 1-3.
www.tainstruments.com/pdf/literature/TN056.pdf
5-Brown S., Cole I., Daniel V., King S., Pearson C.,2001. Guidelines for Environmental Control in Cultural Institutions - Consortium for Heritage Collections and their Environment. Heritage Collections Council, Collections Development Section, Department of Communications, Information Technology and the Arts, Australia, 10-11.
6-Cassar M., and Hutching J., 2000. Relative Humidity and Temperature Pattern Book. The Museums & Galleries Commission (MGC), London, 2000, 4.
7-Dostal J., 2013. Climatic Unit Control. Diploma Thesis, Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Control Engineering, Climatic Unit Control, (Prague), 53-54.
8-Elgaoudi H., Kourkoumelis N., Varella E., Kovala-Demertzi D., 2011. The effect of thermal aging and color pigments on the Egyptian linen properties evaluated by physicochemical methods. Applied Physics A, 105, 497–507.
9-Feller R. L., 1994. Accelerated aging, photochemical and thermal aspects. USA, The Getty Conservation Institute, 161.
10-Forney C. F.and Brandl D. G. , 1992. Control of Humidity in Small Controlled environment Chambers using Glycerol-Water Solutions. Hort Technology 2 , l, 52-54.
11-Georgianna M., Polytimi L., Panagiotis S., 2007. Azoton™, a Nitrogen climatic cabinetfor the trans-portand safe storage of organic archaeological finds. In: Abstracts of posters at the Copenhagen conference, 19 - 23 November, Museum Microclimates, (eds): T. Padfield and K. Borchersen, The National Museum of Denmark, 10.
12-Greenspan L., 1977. Humidity Fixed Points of Binary Saturated Aqueous Solutions. Journal of Research of the National Bureau of Standards - A. Physics and Chemistry 81 A, 1, 89-96.
13-Henderson J., 2007. Managing the library and archive environment. Preservation Advisory Centre, The British Library, London, 4-5.
14-Hyland R. W., C. and Hurley W., 1983. General Guidelines for the On-Site Calibration of Humidity and Moisture Control Systems in Buildings. U.S. Department of Commerce, National Bureau of Standads, U.S. Government Printing Office, Washington DC 20234, 10.
15-Jialu C., 2011. Broadband Dielectric Properties of Impregnated Transformer Paper Insulation at Various Moisture Contents. Master's Degree Project, Electromagnetic Engineering, School of Electrical Engineering, Kungliga Tekniska Hogskolan, Stockholm, Sweden, 56-57.
16-Jowitt R. and Wagstaffe P. J., 1989. The Certification of the Water Content of Microcrystalline Cellulose (MCC) at 10 Water Activities. Commission of the European Communities, EUR 12429 EN, Luxembourg, 10.
17-Lampropoulos V., Kontonikoli M., Papadimitriou M., Karampotsos, A., 2007. Preservation conditions of roman glass vessels of 1stcentury ad from Rhodes Island – Greece. In: Abstracts of posters at the Copenhagen conference, 19 - 23 November, Museum Microclimates, (eds): T. Padfield and K. Borchersen, The National Museum of Denmark, 19.
18-Quincot G., Azenha M., Barros J., Faria R., 2011. Use of salt solutions for assuring constant relative humidity conditions in contained environments. Projetos De Investigacao Cientifica E Desenvolvimento Tecnologico, União Europeia – Fundos Estruturais, Governo da República Portuguesa , Guimarães, UM , 1-3.
19-Rimmer M., and Wang Q., 2010. Assessing the effects of alkaline desalination treatments for archaeological iron using scanning electron microscopy. The British museum, Technical Research Bulletin 4, 79.
20-Romano F., Gaudenzi M.,  Joppolo C.M. Romano L. P., 2013. Temperature and humidity in museum display case: a simulation tool and experimental validation.  Built Heritage, Monitoring Conservation Management, 1329-1335.
21-Slade S., 2003. Temperature and Humidity. Museums Australia Victoria, Scottish Museums Council Fact Sheet – adapted for use in Australia, 1.
 
22-Trustees of the Royal Air Force Museum, RAFM 2008. The Royal Air Force  Museum’s Policy for Monitoring Relative Humidity and Temperature. Environmental Monitoring Policy - RH and Temperature, London, RAFM/DCM/2/6/25/1, 1-3.
23-Wexler A., and Hasegawa S., 1954. Relative Humidity-Temperature Relationships of Some Saturated Salt Solutions in the Temperature Range 0 to 50 C. Journal of Research of the National Bureau of Standards 53, 1, 19-26.